Input handling must preserve the calibration before any model, convolution or likelihood is evaluated. The public Instrument.from_matrix, Observation.from_matrix and OGIP file loaders use the same physical units: energies in keV, effective area in cm² and exposure in seconds. Plain arrays and legacy columns without units use those defaults. Explicit Astropy/FITS units are converted; incompatible units fail with the relevant field name.

Counts must be nonnegative integer events. Count Quantities are converted to counts, while dimensionless extraction scales accept units such as percent. Grouped source and background counts remain exact int64 values; an overflowing sum is rejected. Background-subtracted spectra cannot use this likelihood. Supplied error estimates do not make raw event counts unsuitable for a Poisson fit. Under the PHA header specification, a STAT_ERR column without POISSERR=True specifies supplied errors. These files, and files declaring POISSERR=False, load with a warning that the Poisson likelihood ignores those error settings and uses the event counts. This supports raw counts with pipeline-generated errors, such as CIAO Gehrels estimates; fractional counts and background-subtracted spectra remain rejected.

Background groups are refined only when the source/background ratio differs between usable channels. Bad-quality channels do not introduce boundaries. This can increase the number of bins beyond the supplied grouping, potentially leaving fewer counts in each bin. A UserWarning reports the number of added groups and the old and new totals. The split preserves one source/background scaling ratio per likelihood bin instead of averaging unequal ratios; no warning is emitted when the supplied groups already satisfy this condition. Detector AREASCAL multiplies redistributed counts before grouping, including when pileup recomposes the response from its separate components.

PHA QUALITY and GROUPING columns take precedence over their header keywords. The zero-valued keywords supply defaults only when the corresponding column is absent, so stale header values cannot discard per-channel flags or grouping.

The OGIP response specification defines F_CHAN as the first detector label in a contiguous group, N_CHAN as its length and N_GRP as the number of active groups. Consequently, a response group beginning at channel 12 with two entries maps to labels 12 and 13 even if the EBOUNDS rows are [10, 12, 13]. A group beginning at 10 with two entries is invalid for those EBOUNDS: label 11 is absent. The loader rejects it instead of clipping or shifting its weights. Actual EBOUNDS labels also allow older files without the later TLMIN convention to remain unambiguous.

Fixed and variable-length compressed rows, scalar one-entry columns and empty N_GRP=0 rows are supported. Only active elements are interpreted; unused fixed-width padding does not enter the response. Multiple MATRIX extensions currently raise a clear unsupported-format error rather than discard all but the first. This is a current implementation limit, not a claim that such files violate OGIP.

The loader checks finite nonnegative active weights and areas, ordered photon-energy bins, unique integer channel labels and a positive scalar exposure. Zero area, zero lower energy edges and response columns whose sums differ from one remain valid. It does not renormalize a supplied RMF. Without an ARF, the caller selects the combined-RSP convention, which factors the supplied response into its area and redistribution. Explicit area-valued MATRIX units or HDUCLAS3=FULL reject an additional ARF because that would apply effective area twice. A unitless, unclassified legacy file still requires the caller to know whether an ARF is needed.

Nominal detector EBOUNDS are checked per channel and retain their original label order. They need not increase with energy: RGS wavelength channels have decreasing energy bounds. Sorting those rows by energy would misalign the PHA and response. The ascending/nonoverlap rule applies to the incident photon grid, not to the detector's labeling convention.

Redistribution MATRIX columns with unrecognised FITS unit labels, such as none or au, or with count/photon units are read as unitless with a warning. Their weights are unchanged. Recognised incompatible units such as seconds, metres or keV remain errors. Unknown units and count/photon labels are also rejected on complete (HDUCLAS3=FULL) responses, where they leave the collecting-area scale ambiguous. Recognised area units are converted to cm².

One documented legacy convention can be read without a warning. The CXC source-catalog product documentation labels ACIS redistribution matrices au. An au MATRIX with the complete CHANDRA/ACIS, OGIP, RESPONSE/RSP_MATRIX/REDIST header context is interpreted as dimensionless and records the convention used. The values and source file stay unchanged. DataRMF retains matrix_unit_original and compatibility_notes; Instrument.attrs exposes response_matrix_unit_original and response_matrix_compatibility_notes, including the primary source URL. Other au contexts follow the warning/error rules above. This exception never makes the response an effective-area matrix or replaces its ARF.

Adjacent calibration boundaries sometimes differ by storage roundoff, as in float32 NuSTAR ARF products. Validation accepts overlap up to one relative machine epsilon of the original input dtype, capped at 1% of either adjacent width. The values themselves are retained exactly. Larger overlap, reversed bins and nonfinite edges are rejected. Canonical float64 storage is constructed only after this native-precision check.

Optional associated-file lookup still loads an existing named ARF, RMF or background file. Optionality affects only a missing-file error. Lookup accepts the exact name or its .gz counterpart; similarly prefixed backups are not substituted. Simulated observations inherit the instrument's actual channel labels. Observation configurations expose e_min_channel and e_max_channel on every raw instrument_channel, aligned to the grouping matrix columns. Rejected and excluded columns remain present with zero grouping weights, so detector-background integration can preserve gaps inside a grouped bin.

Offline checks are in test_ogip_units.py, test_ogip_rmf_groups.py, test_response_validation.py, test_detector_channels.py, test_ogip_paths.py, test_ogip_mock.py and test_obsconf_detector_energies.py. They include independent folded-count calculations and deliberately malformed FITS fixtures. These tests can run without a local XSPEC installation or private observation files.